Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
Hand finished  
craftsmanship  
Classic stainless  
steel finish  
Welded seams and  
hemmed edges  
Backdraft damper  
Decorative rail  
(optional)  
Model PWC362418  
Stainless steel  
baffle filters  
Model PWC362418R  
Rail Option  
Location of  
rating plate  
Recessed easy-  
access controls  
Halogen lighting  
Infinite-speed  
blower control  
Model PWC362418R shown with decorative rail  
Wolf Pro wall chimney hoods provide the ultimate  
in ventilation. With standard elements like heat sentry  
and dual setting halogen lighting, Wolf elevates the  
need for ventilation to an enjoyable perk.  
Wolf Pro wall chimney hoods are  
available in the classic stainless steel  
finish. Rail option hoods (R) come with a  
classic stainless steel decorative rail and  
stand-offs. Optional platinum or brass  
rails match dual fuel range bezels. Pro  
wall chimney hoods are sold as a shell  
only, internal, in-line and remote blower  
options are available.  
The Pro wall chimney hood installed with an optional  
6" (152), 12" (305), 18" (457) or 24" (610) classic  
stainless steel duct cover completes the chimney  
design. With the Pro wall chimney hood you also have  
the option of a decorative rail. While a classic stainless  
steel rail is standard on the (R) model, platinum or  
brass rails are also available to match the bezels of our  
dual fuel ranges.  
Pro wall chimney ventilation hoods are recommended  
for use with all Wolf cooking appliances.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
6/07  
 
Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
B L O W E R O P T I O N S  
S P E C I F I C A T I O N S  
Overall Width of Hood  
Overall Height of Hood  
600 CFM Internal Blower  
as of Fall 2007  
801644  
801314  
36" (914)  
18" (457)  
900 CFM Internal Blower  
as of Fall 2007  
801645  
801315  
Overall Depth of Hood – PWC362418  
PWC362418R (including rail)  
24" (610)  
26" (660)  
1100 CFM In-Line Blower  
900 CFM Remote Blower  
1200 CFM Remote Blower  
1500 CFM Remote Blower  
808332  
801641  
801642  
804701  
Internal Blower Options  
In-Line Blower Option  
600 or 900 CFM  
1100 CFM  
Remote Blower Options  
Discharge  
900, 1200 or 1500 CFM  
Vertical  
Refer to Pro Ventilation Recommendations  
at the end of this section.  
Duct Size  
10" (254) Round  
Electrical Supply Requirements  
110/120 V AC, 60 Hz  
15 amp dedicated circuit  
A C C E S S O R I E S  
Shipping Weight (shell only)  
78 lbs (35 kg)  
Platinum or brass decorative rail  
and stand-offs  
Specifications are subject to change without notice.  
38" (965) high stainless steel  
backsplash with warming racks  
38" (965) high stainless steel  
backsplash  
6" (152), 12" (305), 18" (457) and  
24" (610) duct covers  
Accessories are available through your  
Wolf dealer. To obtain local dealer  
information, visit the Locator section of  
our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
 
Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
I N S T A L L A T I O N S P E C I F I C A T I O N S  
LOCATION OF  
6"  
E
ELECTRICAL (152)  
5"  
(127)  
18" (457)  
HEIGHT  
OF HOOD  
36" (914)  
WIDTH OF HOOD  
30" TO 36"  
(762–914)  
30" TO 36"  
(762–914)  
24" (610)  
DEPTH OF HOOD  
TO COUNTERTOP  
TO COUNTERTOP  
NOTE: Pro wall chimney hoods have a vertical discharge.  
D I M E N S I O N S  
Overall Width of Hood  
36" (914)  
Overall Height of Hood  
18" (457)  
24" (610)  
Overall Depth of Hood (excluding rail)  
Countertop to Bottom of Hood  
Location of Electrical  
30" (762) to 36" (914)  
Within shaded area  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
 
Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
IMPORTANT NOTE: Install this ventilation hood  
for overall dimensions and installation specifics.  
only with a Wolf blower.  
Wolf Pro wall chimney ventilation hoods are  
recommended for use with any Wolf cooking  
appliance, and should be as least as wide as  
the cooking surface. It is recommended that the  
hood overlap the cooking surface by 3" (76) on  
either side.  
Pro wall chimney hoods require a separate,  
grounded 110/120 V AC, 60 Hz power supply.  
The service should have its own 15 amp circuit  
breaker. Placement of the electrical supply is  
not critical, as long as you provide enough 120  
V AC, 60 Hz power cable to make the electrical  
connection. Locate electrical within the shaded  
area shown in the Installation illustration.  
Optional 6" (152), 12" (305), 18" (457) and  
24" (610) duct covers are available as a sales  
accessory to complete the chimney design.  
You must follow all National Electrical Code  
regulations. In addition, be aware of local codes  
and ordinances when installing your service.  
Installation of all Pro wall chimney hoods  
should be 30" (762) to 36" (914) from the  
bottom of the hood to the countertop. Follow  
the dimensions shown in the Installation  
illustration.  
Refer to the installation instructions shipped  
with each Wolf product for detailed specifica-  
tions. This information can also be found on  
our website, wolfappliance.com.  
Wolf Pro wall chimney hoods are shipped  
without a blower assembly. Internal, in-line or  
remote blower assemblies are available. Blower  
options also vary with the volume of air that  
needs to be moved and the length of the duct  
run. Refer to page 8 for Pro Ventilation CFM  
Recommendations and Blower Options.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
 
Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
D U C T I N G C O N S I D E R A T I O N S  
Wolf Pro wall chimney ventilation hoods are  
shipped without the blower assembly. Internal,  
in-line and remote blower assemblies are  
available.  
Local building codes may require the use of  
make-up air. Consult your local HVAC profes-  
sional for specific requirements in your area.  
IMPORTANT NOTE: Wolf Pro wall chimney  
hoods must be vented to the outside. Use only  
metal ductwork.  
IMPORTANT NOTE: Install this ventilation hood  
only with a Wolf blower.  
Wolf Pro wall chimney hoods have a vertical  
discharge location with 10" (254) round duct.  
A transition with backdraft damper is included.  
The hood will operate most efficiently when  
ductwork does not exceed 50' (15 m) in length.  
Refer to the illustration below for ducting  
considerations for Pro wall chimney hoods.  
Ducting for Pro wall  
chimney hoods.  
DUCTWORK INSTALLATION  
THROUGH ROOF  
ROOF CAP OR REMOTE BLOWER  
10" (254) ROUND DUCT  
TRANSITION  
14"W x 93/4"D TO 10" ROUND  
7"H (INCLUDING FLANGES)  
SOFFIT OR CABINET  
OR DUCT COVER  
VERTICAL DISCHARGE  
3
18" (457)  
HEIGHT  
16 /4" (425)  
WALL HOOD  
TOP OF WOOD  
OF HOOD  
MOUNTING STRIP  
24" (610)  
DEPTH OF HOOD  
30" TO 36"  
(762–914)  
COUNTERTOP  
TO BOTTOM OF  
VENTILATION HOOD  
36" (914)  
STANDARD  
FLOOR TO  
COUNTERTOP  
HEIGHT  
NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
6
 
Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
W O L F B L O W E R A S S E M B L I E S  
A ventilation system must include a blower  
assembly. Wolf ventilation hoods are shipped  
without the blower assembly. An internal, in-line  
or remote blower assembly must be selected to  
accommodate the cooking appliance, CFM  
requirements and homeowner preferences.  
Internal, in-line and remote blower assemblies  
are available as sales accessories through your  
Wolf dealer.  
Internal blowers are mounted inside the hood  
canopy. In-line blowers are mounted in between  
the hood and the exterior of the home. Remote  
blowers can be mounted on the roof or in some  
cases, on an exterior wall. Refer to the illustra-  
tions below for dimensions of Wolf in-line and  
remote blowers.  
Pro ventilation recommendation charts on the  
following page provide minimum CFM recom-  
mendations according to the cooking appliance  
and ventilation hood used and blower options  
for each specific Pro wall chimney hood.  
IMPORTANT NOTE: Use only a Wolf blower  
with all Wolf ventilation products.  
7
24 /8"  
(632)  
18"  
12"  
(457)  
(305)  
8"  
(203)  
22"  
18"  
(559)  
(457)  
In-line BLOWER-110IL  
21" (533)  
18" (457)  
3
20 /4"  
(527)  
10"  
10"  
(254)  
1
(254)  
1
28 /4"  
1
29 /2"  
29 /2"  
(718)  
(749)  
(749)  
10" (254)  
Diameter  
10" (254)  
Diameter  
10" (254)  
Diameter  
1
15 /2"  
(394)  
3
3
14 /4"  
(375)  
14 /4"  
(375)  
1
1
1
29 /2"  
29 /2"  
24 /2"  
(749)  
(749)  
(622)  
3
1
14"  
10 /8"  
10 /8"  
(356)  
(264)  
(257)  
3
4
/4"  
3
(121)  
24 /4"  
(629)  
1
7
1
25"  
22"  
7
/4"  
/4"  
(635)  
(559)  
(184)  
(184)  
Remote BLOWER-90REM  
Remote BLOWER-120REM  
Remote BLOWER-150REM  
Unit dimensions may vary by 1/8" (3).  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
7
 
Planning Information  
Pro 36" (914) Wall Chimney Hood  
M O D E L P W C 3 6 2 4 1 8 ( R )  
P R O V E N T I L A T I O N C F M R E C O M M E N D AT I O N S  
Pro Wall Chimney Hoods  
Model  
PWC362418  
600  
PWC422418  
600  
PWC482418  
PWC542418  
DF304 / R304 / SRT304  
DF366 / R366 / SRT366 / RT366  
DF364 / R364 / SRT364 / RT364  
RT362  
900  
900  
900  
900  
900  
900  
R488 / RT488  
1100  
1100  
1100  
1100  
1100  
1100  
DF486 / R486 / SRT486 / RT486  
DF484 / R484 / SRT484 / RT484  
Minimum CFM requirements for Wolf ranges and rangetops. Additional CFM may be required for charbroilers, griddles  
and long duct runs.  
P R O V E N T I L A T I O N B L O W E R O P T I O N S  
Pro Wall Chimney Hoods  
Blower Description  
600 CFM Internal  
900 CFM Internal  
1200 CFM Internal  
1100 CFM In-Line  
900 CFM Remote  
1200 CFM Remote  
1500 CFM Remote  
Blower Number  
CTBLOWER-60INT (801644 – 810314 as of Fall 2007)  
CTBLOWER-90INT (801645 – 810315 as of Fall 2007)  
IBLOWER-120INT (804703 – 810317 as of Fall 2007)  
BLOWER-110IL (808332)  
Wall Chimney Hood Models  
PWC362418 / PWC422418  
PWC362418 / PWC422418  
PWC482418 / PWC542418  
All Pro Wall Chimney Hoods  
All Pro Wall Chimney Hoods  
All Pro Wall Chimney Hoods  
All Pro Wall Chimney Hoods  
BLOWER-90REM (801641)  
BLOWER-120REM (801642)  
BLOWER-150REM (804701)  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
8
 

Whirlpool Microwave Oven YMH7155XM User Manual
Whirlpool Washer 8316566 User Manual
Whirlpool Washer Dryer LB5300XK User Manual
Winegard Stereo System HD 8800 User Manual
Wolf Spreader FS 0 0 WS 12 M User Manual
XtremeMac MP3 Docking Station 10182007 User Manual
Yamaha Offroad Vehicle FX10MTRY User Manual
Zanussi Refrigerator 110717 User Manual
Zanussi Refrigerator ZT 25 User Manual
Zephyr Ventilation Hood ZRM E36AS User Manual